Skip to content

Light Up: a lit square is not automatically a safe bulb position

Light Up asks you to illuminate every white square while preventing two bulbs from seeing each other. A bulb lights along rows and columns until a black square blocks the ray; light does not turn around a corner.

← All guides
Light Up: a lit square is not automatically a safe bulb position
Light Up: a lit square is not automatically a safe bulb position. Original editorial schematic; not a captured game board.

Lighting and mutual visibility

Light Up asks you to illuminate every white square while preventing two bulbs from seeing each other. A bulb lights along rows and columns until a black square blocks the ray; light does not turn around a corner.

Consider two white squares in the same uninterrupted corridor. A bulb in either lights the other, so putting bulbs in both violates the visibility rule even though the corridor looks completely illuminated.

A numbered corner can force bulbs

A black corner square marked two, with exactly two white orthogonal neighbors, forces a bulb in each neighbor. Those two bulbs lie diagonally from each other, so they do not see each other through the black corner.

A zero forbids bulbs in its orthogonal neighbors. Those white neighbors still need illumination from another direction; zero is not permission to leave them dark. Unnumbered black squares impose no adjacent bulb count.

Separate prohibition from darkness

A mark can record a place where no bulb is allowed. It does not itself illuminate the square. Conversely, a lit square is not proof that another bulb may be placed there without creating a conflict.

For a doubtful position, trace each straight ray and stop at the first black square. Then check adjacent numbered clues separately. This two-part check catches both mutual illumination and a bulb that exceeds a clue without conflating them.

Replay the blocked ray

On an original Light Up board, choose one uninterrupted corridor and trace what a single bulb illuminates. Check its numbered neighbors separately before adding a second bulb elsewhere. This is an inspection task, not a claim that we completed that board.

In the checklist, name the corridor endpoints, any blocking black square and the action that produced a red warning. Record whether the issue concerns two visible bulbs or an adjacent number.

Official references

References checked: . Original editorial schematic; not a captured game board.

Put it into practice

Open a detail page, check the controls and content notes, then follow the creator’s play link.

Find a game See how it works